Impedance spectrometer (EIS/FRA)

A new generation of impedance spectrometer

eis 2 fra impedance spectrometer 1 5 10 40 100 amps volt sofc soec PEM pefc fuel cell measurment PV solar material science ceramic wet electro chemistry redox battery battries stack single cell four point measurement bode plot high low frequency

Fiaxell is happy to present a new generation of impedance spectrometer (EIS/FRA) specially dedicated for fuel cell research & development.

Why does this product match fuel cell research ?

eis 2 fra impedance spectrometer 1 2 5 10 40 100 amps sofc soec PEM pefc fuel cell electrochemistry electrochemical measurment PV soler cell wet chemistry redox battery battries stack single cell four point measurment bode plot hgh low frequencyImpedance spectrometer for fuel cell research & development

Available in 1, 2, 5 and 10 Ampere units (40 A with booster), our impedance spectrometer with integrated galvanostat / potentiostat allows all tests from button cells up to industrial cell size stack. 

Frequency range FRA/EIS: 10µHz to 1MHz (convenient for most fuel cell testing)

Floating operation, no need of ground, avoids parasitic losses

WE/RE/S/CE,  4-electrodes configuration

In/out: Analog and digital i/o, see below for technical specifications

Slim, small & light weight:

eis 4 fra impedance spectrometer 1 2 5 10 40 100 amps sofc soec PEM pefc fuel cell electrochemistry electrochemical measurment PV soler cell wet chemistry redox battery battries stack single cell four point measurment bode plot hgh low frequencyScientist walking to another building for data acquisition

Easily transportable by hand due to its reduced dimension and weight  (13 x 27 x 4 cm X 1.5 kg) 

One instrument can be shared between test rigs and labs

Thick walled aluminium housing, virtually unbreakable

Extremely reliable, delivered with 3 years warranty

EU fabrication and designed by experienced EIS engineers

Cost effective and affordable for all labs (20-60 % less expensive than market prices- ask us for an offer)

Example of EIS measurement:

eis 5 fra impedance spectrometer 1 2 5 10 40 100 amps sofc soec PEM pefc fuel cell electrochemistry electrochemical measurment PV soler cell wet chemistry redox battery battries stack single cell four point measurment bode plot hgh low frequencyEIS measurement of a SOFC cell in the Open Flanges Set-up™ from Fiaxell. The cell is measured at 1, 2 and 5 Amps from 100 KHz up to 50 mHz

Smooth curves are obtained allowing equivalent circuit fitting with great accuracy

Stability & reproducible resultsfrom high to low frequency without interruption

Intuitive and powerful software:

impedance spectrometer eis fra electrochemistry equivalent circuit 1Equivalent circuit fitting and simulation, easy to build up

Easy to import/export data, all format included such as Zview, Zplot

Batch mode allows scheduling measurements and configuring experimental sequences

Can be controlled from LabVIEW, C++, Delphi, etc.

In conclusion, a product that makes everybody happy

eis 8 fra impedance spectrometer 1 2 5 10 40 100 amps sofc soec PEM pefc fuel cell electrochemistry electrochemical measurment PV soler cell wet chemistry redox battery battries stack single cell four point measurment bode plot hgh low frequencyScientist just walking back from her EIS measurementsCan be shared between different test rigs/labs

Provide reliable and reproducible results

Intuitive and powerful software

EU fabrication, engineered by EIS PhD scientists

Virtually unbreakable, delivered with 3 years warranty

Cost effective for all labs, from 20 up to 60 % less expensive than standard instruments on the market

.... visit us for a product demonstration or ask for a quotation ?

Hardware specifications:

Potentiostat: 
Applied potential range ±10 V, at 0.333mV resolution
Applied potential accuracy 0.2%, or 2 mV
Current ranges ±10 nA to ±100 mA (±1A, ±10A)
Measured current resolution 0.015% of current range, minimum 15pA
Measured current accuracy 0.2%

Galvanostat: 
Applied current resolution 0.033% of applied current range
Applied current accuracy 0.2%
Potential ranges ±10 mV, ±100 mV, ±1 V, ±10 V (±20V)
Measured potential resolution 0.004% of potential range, minimum 0.4µV
Measured potential accuracy 0.2%, or 2mV

Impedance Analyser: 
Frequency range 10µHz to 1MHz
Amplitude 0.015mV to 1.0V, or 0.03% to 100% of current range
DC offset 16 bit dc offset subtraction, and 2 dc-decoupling filters

Miscellaneous:
Automatic current range selection: 1pA to 1A/1mV to 10V 
Automatic variable noise filter and potentiostat/galvanostat stability settings
Simultaneous acquisition of current/potential and peripheral signals
Real time data display up to 500 pnts/s. Acquisition up to 100,000 pnts/s is stored in instrument memory
Applicable scan rates: 1µV/s to 10,000 V/s
Minimum interval time/resolution: 10µs
Result optimisation by automated tuned filters, gain amplifiers and dc-subtraction

Environment:
Power requirements 100-240 V, 50-60 Hz, 700mA (supply included)
Size, weight w x d x h = 13 x 27 x 4cm, 1.5 kg (1 A model)
PC requirements Windows XP/Vista/7/8, with free USB port

Contact us for further information on hardware specifications

Download the brochure:

eis fra impedance spectrometer 1 2 5 10 40 100 amps sofc soec PEM pefc fuel cell electro chemistry electro chemical PV solar cell wet chemistry redox battery batteries stack single cell four point measurement bode plot high EIS 1 fra impedance spectrometer 1 2 5 10 40 100 amps sofc soec PEM pefc fuel cell electro chemistry electro chemical PV solar cell wet chemistry redox battery batteries stack single cell four point measurement bode plot.png

Click on the picture to download the brochure or click here to go to all Fiaxell brochures 

Stay informed

Subscribe to the newsletters & get special discounts

Address

Fiaxell 
SOFC Technologies
PSE A
1015 Lausanne
Switzerland

More information

Contact details

Phone (lab): +41 78 677 56 05
Phone (admin): +41 21 647 48 38

  info@fiaxell.com
  Follow us on Linkedin

Privacy policy

Contact Us